Menu

Monofunction simulator Type UC TC.2

 

Product description

Possible areas of application Monofunction simulator Type UC TC.2

SIKA simulators have been developed for simple and flexible calibration and maintenance. Various tests can be performed in a single operation without having to change instruments. This saves time. Our mono-functional simulators are especially useful if you only require one signal type.

Main applications

  • Service, maintenance and repair
  • Quality assurance
  • Testing laboratories and research
  • Instrumentation and control
  • Process industry
  • Energy supply
  • Machine and apparatus engineering

Numerous other applications are also possible.

 

Description

Multifunction display
The back-lit multifunction display ensures clear indication of input and output values as well as all adjustments.

Operating concepts
Features include a rubber keypad, convenient interactive menu control via function keys, navigator and numeric keypad. These features allow easy selection and display of numerous functions.

Steps and ramps
An automatic program is generated for periodic calls. The type of signal, duration and value are defined. Start delay, number of repetitions and a continuous linear increasing or decreasing characteristic can be individually programmed.

High-speed call
Signal values needed time and again are permanently or flexibly stored in the simulator and can be recalled quickly at the push of a button.

Synthesizer
The synthesiser function can be used for the generation of a discontinuous characteristic with changing signal values. Previously programmed changing signal levels are displayed on the simulator.
This function allows the simple definition and successive call of different steps, ramps or synthesiser values for easier testing.

Calibration and linearisation points
If the measuring characteristics and deviations of a sensor are known and these are available in the form of a calibration certificate, they should be taken into account in measurement to obtain accurate measuring results.

The simulator input can be shifted linearly by offset programming to approach the measuring characteristics of the sensor. This single-point calibration is the simplest and most popular method for improving measuring results.

Multipoint calibration can be used for greater measuring accuracy. The input is configured by means of four linearisation points to the real sensor characteristics to compensate for linearity errors. Up to five different calibration data files can be directly stored and easily recalled as required.

Technical features

Technical features

Thermocouples (TC)
TC signal generation and measurement J, K, T, R, S, B, N, E, U, L, C

mV generator function -9.5...80 mV
mV measurement function -10...100 mV
Accuracy (of rdg. + const.) ±0.02 %
Selectable temperature unit °C / °F
Internal comparison point ±0.3 °C

 

Functions at generation
High-speed call values 10 points (flexible)
Linear steps and ramps yes
User-defined synthesiser values 10
User-defined signal output characteristic 10 points

Editable units yes
Functions at measurement
Data memory 10 000 values
Value tables and graphics function yes
Sensor characteristic offset programming yes

Calibration data files and linearisation points 5 x 4 values

User-defined measuring input characteristic 10 points

Editable units yes
Measured value min. / max. yes
Measured value hold function yes
Averaging function yes

 Operator guidance

  • Menu with pull-down windows
  • Programming and control via PC

Battery supply / Operating time

  • About 40 h

Accu set with mains adapter (optional)

Software (optional)

 

Further details and accessories can be found in the datasheet.

Contact

Contact us

 
For inquiries or further informations please contact our product specialists by using the contact form below. Thank you!
Please fill all required fields*.
 
Go to top