Multifunction simulator Type MC 75.2

 

Product description

Possible areas of application Simulator MC 75 2

SIKA simulators have been developed for simple and flexible calibration and maintenance. Various tests can be performed in a single operation without having to change instruments. This saves time. SIKA multifunction simulators combine the functions of a wide range of individual devices into a single unit.

Main applications

  • Service, maintenance and repair
  • Quality assurance
  • Testing laboratories and research
  • Instrumentation and control
  • Process industry
  • Energy supply
  • Machine and apparatus engineering

Numerous other applications are also possible.

 

Description

Steps and ramps
An automatic program is generated for periodic calls. The type of signal, duration and value are defined. Start delay, number of repetitions and a continuous linear increasing or decreasing characteristic can be individually programmed.

High-speed call
Signal values needed time and again are permanently or flexibly stored in the simulator and can be recalled quickly at the push of a button.

Synthesizer
The synthesiser function can be used for the generation of a discontinuous characteristic with changing signal values. Previously programmed changing signal levels are displayed on the simulator.
This function allows the simple definition and successive call of different steps, ramps or synthesiser values for easier testing.

Calibration and linearisation points
If the measuring characteristics and deviations of a sensor are known and these are available in the form of a calibration certificate, they should be taken into account in measurement to obtain accurate measuring results.

The simulator input can be shifted linearly by offset programming to approach the measuring characteristics of the sensor. This single-point calibration is the simplest and most popular method for improving measuring results.

Multipoint calibration can be used for greater measuring accuracy. The input is configured by means of four linearisation points to the real sensor characteristics to compensate for linearity errors. Up to five different calibration data files can be directly stored and easily recalled as required.

User-defined characteristics
Measurement is often based on ideal linear characteristics. In normal practice, sensors, transmitters, transducers, etc., are often subject to non-linear characteristics due to various offset, gradient, linearity or hysteresis errors. For the faultless measurement or generation of such non-linear characteristics, the measuring input or signal output can be configured with up to ten points by the user. The unit relating to the value is freely editable.

Technical features

Technical features

Resistance thermometer (RTD)
RTD signal generation and
measurement
Pt50, Pt100, Pt200, Pt500, Pt1000, Cu10, Cu50, Ni100, Ni120, Ni1000

Ω generator function 0...4000 Ω
Ω measurement function 0...4000 Ω
Accuracy (of rdg. + const.) ±0,012 %
Selectable temperature unit °C / °F
Measurement of multi-wire 2 / 3 / 4
Thermocouples (TC)
TC signal generation and
measurement
J, K, T, R, S, B, N, E, U, L

mV generator function 0...100 mV
mV measurement function 0...100 mV
Accuracy (of rdg. + const.) ±0,013 %
Selectable temperature unit °C / °F
Internal comparison point ±0,3 °C
Current (mA)
Loop current signal generation 0(4)...24 mA
Loop current signal measurement 0(4)...50 mA
Accuracy (of rdg. + const.) ±0,0175 %
Current loop supply 24 V ±10 %, 22 mA
HART compatible internal loop
resistor
250 Ω

Voltage (V)
Voltage signal generation 0...20 V
Voltage signal measurement 0...50 V
Accuracy (of rdg. + const.) ±0,015 %
Continuity (O / C)
Continuity measurement O / C
Switching threshold "open" 1 kΩ
Frequency and pulse (Hz)
Frequency and pulse signal
generation
0,01 Hz...10 kHz

Frequency and pulse signal
measurement
0,01 Hz...20 kHz

Accuracy (of rdg. + const.) ±0,005 %
Pressure signals (bar)
Pressure measurement with external
pressure module
yes
 
Editable pressure units yes
Connection via DIN socket 5-pin

 

Functions at generation
High-speed call values 10 points (flexible)
Linear steps and ramps yes
User-defined synthesiser values 100
User-defined signal output
characteristic
10 points

Editable units yes
Transmitter function simulation yes
Functions at measurement
Data memory 10 000 values
Value tables and graphics function yes
Offset programming for sensor characteristic yes
 
Calibration data files and
linearisation points
5 x 4 values
 
User-defined measuring input
characteristic
10 points
 
Editable units yes
Measured value min. / max. yes
Averaging function yes

Operator guidance

  • Separate channels for parallel signal processing
  • Menu with pull-down windows
  • Programming and control via PC
  • Graphic display of connection options
  • Configuration files for test adjustments (10)
  • Test report generation / Calibration routines (10)

Battery supply / Operating time

  • About 20 h with Auto-Power off

Software (optional)

Further details and accessories can be found in the datasheet.